- Butt welding fittings
- bends
- T- X- Y- pieces
- T- and Y-bends
- reducers
- caps and heads
- collars
- branch saddles
- orbital fittings
- ANSI / ASME
- Industrial valves
- ball valves
- actuators
- drain cocks
- gate valves
- globe valves
- non-return valves
- Y-strainers
- control technology
- Flanges
- welding neck flanges
- threaded flanges
- blind flanges
- plate flanges
- loose plate flanges
- collars
- flange-fittings
- ANSI/ ASME
- other
- Systems
- TEEKAY
- Victaulic
- press fittings
- quick couplings
- clamp connections
- cutting rings
- DIN 11864/ DIN 11853
- railing construction
- Beverage fittings
- unions
- fittings
- pipe clamps
- Tri-Clamp
- valves & cocks
- flange connections
- inspection glasses
- filter & strainers
- spray balls
electric actuatorEANT10
electric actuator J2 series, model 10 > protection class: IP 65 > 2 volt-free limit switches
> manual override > heater > electric torque limiter > connection acc. ISO 5211 > multi flange F03/F05 (Please notice the operating manual!)
Series J2 Model 10 | Properties |
---|---|
Voltage range L [-0%/+5%] | 24V AC/DC |
Voltage range H [+/-5%] | 110-240V AC/DC |
Current consumption | min. 0,2 A - 0,28 A |
Running time (s/90°) [+/-10%] | 16 s |
Heating | 3,5 W |
Breakaway torque | 12 Nm |
Working torque | 10 Nm |
Duty cycle [ED]* | 75% |
Type of protection | IP 65 |
Temperature range | -20°C bis +70°C |
Connection | DIN 43650, ISO 4400, C-192/C-193 |
Housing | Polyamid (PA6) |
LxWxH | 172x125,5x104 |
with 8-edge consumption | 14 mm |
Consumption depth | 17 mm |
Flange pattern | F05/F07 |
Duty cycle
After each run time of the actuator, a break of 25% of the total running time is necessary
to avoid damaging the drive.
Designation | Time | On-drive 0°-90° | On/Off-drive 0°-90°-0° |
---|---|---|---|
Running time (75%) | 16 s | 1 | 0 |
Break (25%) | 4 s | 1 | 0 |
Total time (100%) | 20 s | 1 | 0 |
per minute | 60 s | 3 | 2 |
per 10 minutes | 600 s | 30 | 15 |
per hour | 3600 s | 180 | 90 |
-> 3600 s : 20 s = 180 drives
Features:
• ETL: Electronic Torque Limiting
The electronic torque limiter protects valves and actuators against damage from overloading.
• AVS: Automatic Voltage Sensing
All voltages are covered automatically and without configuration by two voltage variants.
The running times and torques remain unchanged in this case.
• ATC: Automatic Temperature Control
Including switching room heater. If the voltage is not switched off externally, the automatic
switching space heater works to prevent the formation of condensed water buildup inside
the actuator.
• Unlocked mechanically
The gearbox is unlocked when the protection circuit of the limiter is activated or when the end
position is reached (rotated in reverse) in order to allow an easy transition from the automatic
mode to the manual mode. The self-inhibiting property of the actuator is unchanged.
• Low-ear, corrosion-resistant, and high-strength housing made of nylon.
• High stiffness (self-inhibiting)
• Manual override
• Two limit switches for controlling the motor with electronic motor cut-off
• Two limit switches for reporting the position
Wiring
The standard circuit diagram provides a 3-wire circuit for AC and DC.
Alternatively, a 2-wire DC wiring is possible.
> 2 volt-free limit switches
> manual override
> heater
> electric torque limiter
> connection acc. ISO 5211
> multi flange F03/F05
(Please notice the operating manual!)
extended product description
dimension | File Download (3D-PDF) | File Download (STEP) |
---|---|---|
85-240V | heco_EANT-010-H.pdf | heco_EANT-010-H.step |
24V | heco_EANT-010-L.pdf | heco_EANT-010-L.step |
ball valves with actuator electric actuators 10 Nm
electric actuatorEANT10
> heater
> electric torque limiter
> connection acc. ISO 5211
> multi flange F03/F05
(Please notice the operating manual!)
Series J2 Model 10 | Properties |
---|---|
Voltage range L [-0%/+5%] | 24V AC/DC |
Voltage range H [+/-5%] | 110-240V AC/DC |
Current consumption | min. 0,2 A - 0,28 A |
Running time (s/90°) [+/-10%] | 16 s |
Heating | 3,5 W |
Breakaway torque | 12 Nm |
Working torque | 10 Nm |
Duty cycle [ED]* | 75% |
Type of protection | IP 65 |
Temperature range | -20°C bis +70°C |
Connection | DIN 43650, ISO 4400, C-192/C-193 |
Housing | Polyamid (PA6) |
LxWxH | 172x125,5x104 |
with 8-edge consumption | 14 mm |
Consumption depth | 17 mm |
Flange pattern | F05/F07 |
Duty cycle
After each run time of the actuator, a break of 25% of the total running time is necessary
to avoid damaging the drive.
Designation | Time | On-drive 0°-90° | On/Off-drive 0°-90°-0° |
---|---|---|---|
Running time (75%) | 16 s | 1 | 0 |
Break (25%) | 4 s | 1 | 0 |
Total time (100%) | 20 s | 1 | 0 |
per minute | 60 s | 3 | 2 |
per 10 minutes | 600 s | 30 | 15 |
per hour | 3600 s | 180 | 90 |
-> 3600 s : 20 s = 180 drives
Features:
• ETL: Electronic Torque Limiting
The electronic torque limiter protects valves and actuators against damage from overloading.
• AVS: Automatic Voltage Sensing
All voltages are covered automatically and without configuration by two voltage variants.
The running times and torques remain unchanged in this case.
• ATC: Automatic Temperature Control
Including switching room heater. If the voltage is not switched off externally, the automatic
switching space heater works to prevent the formation of condensed water buildup inside
the actuator.
• Unlocked mechanically
The gearbox is unlocked when the protection circuit of the limiter is activated or when the end
position is reached (rotated in reverse) in order to allow an easy transition from the automatic
mode to the manual mode. The self-inhibiting property of the actuator is unchanged.
• Low-ear, corrosion-resistant, and high-strength housing made of nylon.
• High stiffness (self-inhibiting)
• Manual override
• Two limit switches for controlling the motor with electronic motor cut-off
• Two limit switches for reporting the position
Wiring
The standard circuit diagram provides a 3-wire circuit for AC and DC.
Alternatively, a 2-wire DC wiring is possible.
This view is not optimized for mobile devices.
You can change back to desktop view.
This view is not optimized for mobile devices.
You can change back to desktop view.
dimension | File Download (3D-PDF) | File Download (STEP) |
---|---|---|
85-240V | heco_EANT-010-H.pdf | heco_EANT-010-H.step |
24V | heco_EANT-010-L.pdf | heco_EANT-010-L.step |